Genesis Speaker-Strobe Installation Sheet
Description
The Genesis Speaker-Strobe is a fire alarm notification
appliance designed for indoor walls. See Table 1 for a list of
model numbers.
Table 1: Models
Description
Number
Speaker
-Strobe,
25 VRMS, 15 to 110
multi
-cd, white
ADTG4-S2VM MG4-S2VM
EG4-S2VM XLSG4-S2VM
G4-S2VM ZG4-S2VM
Speaker
-Strobe,
25 VRMS, 15 to 110
multi
-cd, white, with FIRE
marking
ADTG4F-S2VM MG4F-S2VM
EG4F-S2VM XLSG4F-S2VM
G4F-S2VM ZG4F-S2VM
Speaker
-Strobe,
70 VRMS, 15 to 110
multi
-cd, white
ADTG4-S7VM MG4-S7VM
EG4-S7VM XLSG4-S7VM
G4-S7VM G4-S7VM
Speaker
-Strobe,
70 VRMS, 15 to 110
multi
-cd, white, with FIRE
marking
ADTG4F-S7VM MG4F-S7VM
EG4F-S7VM XLSG4F-S7VM
G4F-S7VM ZG4F-S7VM
Surface mount box, white
ADTG4B MG4B
EG4B XLSG4B
G4B ZG4B
The speaker-strobe includes field configurable switches for
selecting the desired candela output and wattage tap. These
settings lock in place and remain visible after final installation.
This strobe features an enhanced synchronization circuit to
comply with the latest requirements of UL 1971 Signaling
Devices for the Hearing Impaired and the latest Canadian
standard CAN/ULC-S526. Synchronized operation requires a
separately installed synchronization control module. See
Table 2 for a list of compatible synchronization modules.
Install this device in accordance with applicable requirements
in the latest editions of the NFPA codes and standards and
Canadian Electrical Code, Part 1, Section 32 and CAN/ULC-
S524, Standard for the Installation of Fire Alarm Systems, and
in accordance with the local authorities having jurisdiction.
Table 2: Compatible synchronization module models
Description
Number
Auto
-sync output module
SIGA-CC1S SIGA-MCC1S
GSA-CC1S GSA-MCC1S
Genesis signal master
-
remote mount
ADTG1M-RM MG1M-RM
EG1M-RM XLSG1M-RM
G1M-RM ZG1M-RM
Installation
WARNING: To reduce the risk of shock, disconnect all power
and allow 10 minutes for stored energy to dissipate before
handling.
Caution: Electrical supervision requires the wire run to be
broken at each terminal. Do not loop the signaling circuit field
wires around the terminals.
To install the speaker-strobe:
1. Remove the cover by depressing the tabs on top of the
unit by inserting a small screwdriver from the top and
twisting slightly.
2. If temporal strobe (private mode) operation is desired, cut
jumper JP1. See Figure 2.
3. Connect the speaker and strobe terminals to the signal
circuit field wiring. For the unit to function properly,
observe polarity. See Figure 5.
4. Slide the candela switch to the desired candela output (15,
30, 75, or 95 cd) by aligning it with the indicator below the
switch. See Figure 1.
5. Slide the wattage switch to the desired wattage tap (2 W,
1 W, 1/2 W, or 1/4 W) by aligning it with the indicator
below the switch. See Figure 1.
6. Mount the unit onto a compatible electrical box. See
Figure 4.
7. Replace the cover by aligning it at the bottom and
snapping it in at the top.
8. Test the unit for proper operation.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Installation

© 2013 UTC Fire & Security. All rights reserved. 1 / 4 P/N 3100273 • REV 07 • REB 30JAN13 Genesis Speaker-Strobe Installation Sheet Description

Page 2

2 / 4 P/N 3100273 • REV 07 • REB 30JAN13 Figure 1: Field-configurable switches 1. Candela switch 2. Indicator 3. Wattage switch 4. Bottom Fig

Page 3 - Contact information

P/N 3100273 • REV 07 • REB 30JAN13 3 / 4 Figure 5: Wiring Diagram 1. First speaker-strobe 2. Last speaker strobe 3. EOL resistor, voltage deter

Page 4

4 / 4 P/N 3100273 • REV 07 • REB 30JAN13