Edwards-signaling B-KBH-5040-N5 User Manual

Browse online or download User Manual for Safety Edwards-signaling B-KBH-5040-N5. Edwards Signaling B-KBH-5040-N5 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
P-047550-1607 ISSUE 1
© 1996
CHESHIRE, CT 203-699-3000 FAX. 203-699-3075
Installation Instructions for Catalog No.
B-KBH-5040-N5 Phone Bell
DESCRIPTION
The Edwards B-KBH-5040-N5 Phone Bell is a solid state,
self-contained unit powered by 120V 60 Hz. The unit is acti-
vated by AC or DC voltage through solid state relays. The
phone bell is designed for use in indoor areas that have me-
dium ambient noise level such as warehouses and garages.
The unit is rated at 104 dB at 10 feet (3.05m). The phone bell
is UL listed and comes with strain relief, connectors which
secure the 6 foot (1.83m) power cord to the housing.
These devices are intended for connection to single line tele-
phone or key systems only. They are not intended for use
on "party line" or on coin telephone lines.
When installed in accordance with these instructions, the
devices can be readily disconnected without affecting
equipment remaining on the telephone network.
Registered with the Federal Communications Commission
in compliance with Part 68 of FCC Rules and Regulations.
IMPORTANT TELEPHONE INFORMATION
The following information may be required by the telephone
company: Telephone Number, FCC Registration Number:
3Z9USA-21250-RG-N, Ringer Equivalence Number (REN):
1.5B at greater than 50 Volts and 3.4B at less than 50 Volts.
The REN allows the installer to determine the number of de-
vices that can be added to the telephone line and still have all
the devices ring when the number is called. In most, but not
all, areas the sum of all RENs for all devices connected to
your line should not exceed five. To be sure of the number of
devices you can connect to your telephone line, contact your
local telephone company.
Figure 1. Phone Bell Dimensions
If these devices damage the telephone network, the telephone
company will notify the owner that it may temporarily discon-
nect service if they consider such action necessary. If the owner
considers the disconnection unwarranted, they have the right to
bring a complaint to the FCC.
The telephone company may make changes in its communica-
tion facilities, equipment, operations, or procedures when such
action is required. If these changes render the devices incom-
patible with the telephone company facilities, the telephone com-
pany will provide enough written notice so that necessary
changes can be made in order to maintain uninterrupted ser-
vice.
ELECTRICAL SPECIFICATIONS
Input Max. Switching Max Amps
Cat. No. Desc Voltage Voltage Switch
B-KBH-5040-N5 Remote 10-250 AC 240 AC 5.0
Phone 16-70 Hz
Bell 10-150 DC 48 DC 1.5
INSTALLATION
1. Mount the phone bell to a flat surface using three mounting
screws (not provided).
2. Remove the four #8 x 5/8" (16mm) pan head Phillips screws
and remove the phone bell cover.
3. Wire the phone bell as shown in Figure 2.
4. Replace the phone bell cover and secure with the screws
removed in Step 2.
5. Test the phone bell by dialing the appropriate number or
extension.
MAINTENANCE
CAUTION
This unit is not serviceable or repairable. Should the
unit fail to operate, contact the supplier for replacement.
If this product should fail to operate, disconnect it from the tele-
phone line and determine if the problem is in the telephone line
or the device. If this product is defective, discontinue its use
and obtain a replacement.
Page view 0
1 2

Summary of Contents

Page 1

P-047550-1607 ISSUE 1© 1996CHESHIRE, CT 203-699-3000 FAX. 203-699-3075™Installation Instructions for Catalog No.B-KBH-5040-N5 Phone BellDESCRIPTIONT

Page 2 - P-047550-1607 ISSUE 1

Figure 2. Electrical ConnectionsP-047550-1607 ISSUE 1

Comments to this Manuals

No comments