Edwards-signaling 371-BT Series User Manual

Browse online or download User Manual for Safety Edwards-signaling 371-BT Series. Edwards Signaling 371-BT Series User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
GuardSwitch
Series 300
371-BT
371-BT
Safety Interlock Switch
Installation
Use non-removable screws, bolts, or nuts to mount the switch and actuator. Do not
over-torque mounting hardware.
1. Position the switch and actuator so the labels are reading in the same direction.
(See Figure 1.)
2. Mount the switch on the stationary frame of the machine and mount the actuator
on the moveable guard, door or gate. Keep the switch and actuator within the
listed sense range. (See Ordering Information.)
See Figure 2 or recommended mounting configurations.
3. Mounting on a ferrous material will effect the sense range a minimum of 50%.
However, a 1/4" non-ferrous spacer positioned under the actuator and/or switch
should restore most of the lost sense range.
4. For best protection against operator defeat, mount with non-removable screws,
bolts or nuts (see Accessories).
5. Caution! When not used with a INT safety relay, particular care must be taken to
determine the actual load of the switch circuit. High voltage transients from coils,
motors, contactors, and solenoids must be considered. Transient protection, such
as back-to-back zener diodes (TransZorb
®
) or an RC network, is recommended for
such loads to ensure that maximum ratings of the switch are not exceeded. Not
recommended to be used with tungsten filament loads because of high current
inrush surges. Line capacitance and load capacitance must be considered.
Excessive line capacitance can be caused by cable lengths over 50' when using a
maximum 48 VAC. A resistor can be added in series to limit the inrush current (at
least 48 Ohms for 24V applications). The resistor can be added in series just before
the load. The voltage drop and the power rating of the resistor must be considered.
Voltage drop = I•R; Watts = I
2
R (I = maximum continuous current of the load).
Description
The 371-BT Series DPST safety interlock switch is designed for use with safety
monitored relays or monitored circuits. To achieve the optimum Series 300 defeat
resistant feature of the 371-BT, both the switch cir
cuit (Circuit 1) and the tamper
circuit (Circuit 2) must be connected.
Notes:
1. Environmental: Pollution Degree II
2. Correct use of this control device is an essential part of proper machine cycle
control.
3. Failure to follow ALL instructions could lead to serious bodily injury or death.
4. Maintenance to be done by qualified personnel only
5. The connecting cables between the INT devices and the switches must be located
in an IP 23 type enclosure (minmum).
6. The mounting for the switch and the actuator magnet must be accomplished per
this specification.
7. Non-removable hardware must be used for installation.
8. The housing of the 300-BT must be connected to the PE (Primary Earth) ground
circuit via a lock washer on the mounting screw. The PE ground symbol must be
placed adjacent to the screw.
To verify switch operation with an ohmmeter:
Set range at 20 mega ohms (switches with triac output, set ohm range at 20 kilo
ohms). For a normally open switch, the meter will read a high impedance with the
actuator away. It will read very high to infinity range (triac switches will read high
kilo ohm to infinity range) with the actuator within sense range. You will see the
opposite reading for a normally closed switch.
Dimensions
5.75''
14.61cm
5.27''
13.39cm
0.24''
0.61cm
0.83''
2.11cm
0.42''
1.07cm
5.75''
14.61cm
5.26''
13.36cm
0.24''
0.61cm
0.64''
1.63cm
2.03''
5.16cm
0.64''
1.63cm
2.33''
5.92cm
1.10''
2.79cm
0.28''
0.71cm
1.12''
2.84cm
1.49''
3.78cm
0.22''
0.56cm
dia.
1.51''
3.84cm
www.edwardssignaling.com
P/N 1033317 • REV C • REB 26FEB13
Page view 0
1 2 3 4

Summary of Contents

Page 1

GuardSwitch™ Series 300371-BT371-BTSafety Interlock SwitchInstallationUse non-removable screws, bolts, or nuts to mount the switch and actuator. Do no

Page 2 - Wiring Diagram for Category 3

PerpendicularActuationDoorActuation Parallel ActuationBest Best Not RecommendedPivot ActuationGoodThe parallel actuation can result in on/off/on signa

Page 3 - Wiring Diagram for Category 4

Wiring Diagram for Category 4Inputs shown with safety gate/guard in closed position. Two Series 300-B GuardSwitches™ with one INT relay are required f

Page 4 - Accessories

Ordering InformationPART NUMBER TAMPER PROOF SCREWS & SCREWDRIVER1953 #6 x 3/4"L Tampruf Roundhead Screw1954 #8 x 1-1/2"L Tampruf Roundh

Comments to this Manuals

No comments